■ Design Parameter
How to choose a correct vent housing?
Step 1: Calculate the tank maximum gas volume V
V= | V liquid Inlet - V liquid outlet | max
Step 2: Confirm sterilize membrane filter and its pore size according to application
Step 3: According to △P( Design negative pressure of tank) and V and sterilize membrane filter types( as follows) to choose correct filter specification
GPFL Cartridge |
5 inch |
10inch |
20inch |
30inch |
△P=1KPa |
6 m3/h |
12 m3/h |
24 m3/h |
36 m3/h |
△P=2KPa |
12 m3/h |
23 m3/h |
40 m3/h |
61 m3/h |
For example: if V=21.63m3/h, △P=1KPa, it is better to choose GPFL filter cartridge in 20inch length.
■ Avoid Condensation Sterlize Vent Housing
Constant Temperature Vent Housing is made of vent housing, heating jacket, jacket protection and Electric-heating device.
Advantages:
A. Heat can dry wet filter cartridge and ensure filter flow rate
B. Bacteria cannot survive under high temperturate
C. Advanced heat on stystem
D. Elbow design: avoid outside large particles go into the vent housing and protect the filter cartridge
■ Ordering Information
Please consult sales@cobetterfilter.com for further details on this product.